---
product_id: 29218792
title: "Replacement for Goodman Single Pole / 1 Pole 30 Amp Condenser Contactor B1360321 by Replacement for Goodman"
brand: "replacement for goodman"
price: "AED 120"
currency: AED
in_stock: true
reviews_count: 8
url: https://www.desertcart.ae/products/29218792-replacement-for-goodman-single-pole-1-pole-30-amp-condenser
store_origin: AE
region: United Arab Emirates
---

# Replacement for Goodman Single Pole / 1 Pole 30 Amp Condenser Contactor B1360321 by Replacement for Goodman

**Brand:** replacement for goodman
**Price:** AED 120
**Availability:** ✅ In Stock

## Quick Answers

- **What is this?** Replacement for Goodman Single Pole / 1 Pole 30 Amp Condenser Contactor B1360321 by Replacement for Goodman by replacement for goodman
- **How much does it cost?** AED 120 with free shipping
- **Is it available?** Yes, in stock and ready to ship
- **Where can I buy it?** [www.desertcart.ae](https://www.desertcart.ae/products/29218792-replacement-for-goodman-single-pole-1-pole-30-amp-condenser)

## Best For

- replacement for goodman enthusiasts

## Why This Product

- Trusted replacement for goodman brand quality
- Free international shipping included
- Worldwide delivery with tracking
- 15-day hassle-free returns

## Description

Replacement for Goodman Single Pole / 1 Pole 30 Amp Condenser Contactor B1360321 by Replacement for Goodman

## Technical Specifications

| Specification | Value |
|---------------|-------|
| Contact Type | Normally Open |
| Current Rating | 30 Amps |
| Mounting Type | Pole |
| Brand | Replacement for Goodman |
| Operation Mode | Automatic |
| Wattage | 1 KW |
| Contact Current Rating | 30 Amps |
| Maximum Switching Current | 30 Amps |
| Manufacturer | Universal |
| Part Number | Replaces part # B13603-21 |
| Item Weight | 9.9 ounces |
| Product Dimensions | 6 x 4 x 6 inches |
| Is Discontinued By Manufacturer | No |
| Item Package Quantity | 1 |
| Measurement System | Metric |
| Batteries Required? | No |

## Product Details

- **Contact Type:** Normally Open
- **Current Rating:** 30 Amps
- **Mounting Type:** Pole
- **Brand:** Replacement for Goodman
- **Operation Mode:** Automatic

## Images

![Replacement for Goodman Single Pole / 1 Pole 30 Amp Condenser Contactor B1360321 by Replacement for Goodman - Image 1](https://m.media-amazon.com/images/I/61ZwViBPZ5L.jpg)
![Replacement for Goodman Single Pole / 1 Pole 30 Amp Condenser Contactor B1360321 by Replacement for Goodman - Image 2](https://m.media-amazon.com/images/I/51mRmDMGPYL.jpg)
![Replacement for Goodman Single Pole / 1 Pole 30 Amp Condenser Contactor B1360321 by Replacement for Goodman - Image 3](https://m.media-amazon.com/images/I/51sJg3Y7tPL.jpg)
![Replacement for Goodman Single Pole / 1 Pole 30 Amp Condenser Contactor B1360321 by Replacement for Goodman - Image 4](https://m.media-amazon.com/images/I/51WWEXcLtOL.jpg)

## Questions & Answers

**Q: Is this compatible with a goodman gsc130421ac unit?**
A: This will not work for you, but I have located the part that will: http://www.amazon.com/gp/offer-listing/B0195UK43I/?seller=A3ENSQM9L05QCM&ref=myi_listid_offer

**Q: Will this work with goodman gsh130301ab?  the 'check' says, unknown. thank you.**
A: Yes it will work

**Q: Is this compatible with this number model rcc42c2a**
A: Yes, this will work!

**Q: What replaces contractor four a Goodman cr453cb3hbaag 40 amp**
A: Thanks for the question. We can confirm the part you're viewing is compatible. If you have any more questions, please send us a direct email, and we'll be happy to assist you. If the question is about another part, please be sure to include either the part number currently installed, or the model and serial of the whole system (this is so we can pull up your parts list). Thanks!

## Customer Reviews

### ⭐⭐⭐⭐⭐ Does your central AC condenser / compressor sometimes not turn off? Check your Contactor! Save $$$
*by U***E on July 7, 2023*

This time last year, the condenser unit (the part of the central air conditioning system that's outside, next to the house) of my older central AC started getting stuck "on". The house cooled to the temperature set on the thermostat, and the forced air blower turned off like it should But the outside unit wouldn't shut off until I turned off the breaker. This happened randomly a couple of times over the cooling season, but each time it did, it wasted 2000 to 3000 of watts every hour. That adds up!One common cause of this sort of problem is a sticking contactor. The contactor is what turns the power to your AC condenser on and off when your thermostat tells it to. The contactor is inside a small panel on our AC condenser (the fan box that's on the outside of your house). It has several wires that connect to it: a pair of thick high voltage wires on the input side that come from a disconnect box, some thick high voltage wires on the output side that go to the fan and the compressor, a pair of low-voltage wires that come from your thermostat, and often a wire that goes to a large capacitor nearby. (By the way, all of these can contain dangerous amounds of electricity, even when the power is off, so hands off unless you know what you're doing.)Last year, I tried to fix this problem without replacing anything. This is a job that I felt OK with tackling because my DIY skills are at the level that includes things like attaching a cord to an electric dryer or replacing a light switch.First, I turned off the AC at the thermostat. (CAREFUL! This doesn't turn off the high voltage power in the AC condenser.) Then I opened the access panel on the condenser and gently thumped the contactor with a wooden cooking spoon (because wood doesn't conduct electricity). The contactor unstuck and the AC unit turned off. That confirmed that my contactor was the problem.Then I turned off the power to the AC at the breaker panel and at the disconnect box, and I carefully isolated the capacitor. I then used compressed air to clean out any spiders or other crud that could be jamming the contactor. I then used WD-40 Specialist Contact Cleaner Spray https://amzn.to/3JPJrDD and a long cotton swab to clean things out. Then I sprayed some electrical lubricant https://amzn.to/44wsZAb on the moving parts of the contactor. Then I reconnected the capacitor, closed everything up and powered the system on again.This worked for several months, but the problem came back again this year, and was even more stubborn. I read from several sources that the best fix is to just replace the contactor. After verifying the part numbers, I bought this new Climatec contactor replacement. It arrived in a couple of days.Swapping out the old contactor just involved the same safety steps (turn off ac at the thermostat, breaker panel and shutoff box, isolate capacitor). I unscrewed the old contactor from the wall of the AC condenser and screwed the new one into the same place. Then it was just a matter of swapping out each wire, one at a time, to the same place on the new contactor.After reattaching the capacitor, I powered up the system and checked my work. Everything worked fine. I finished up by putting the access panel back.

### ⭐⭐⭐⭐⭐ Good replacement, saved a lot of money!
*by A***A on March 28, 2020*

Delivered quickly and it was really easy to install. Did one wire at a time, until all wires were transferred and it worked great. The previous one hadn’t failed, but it was showing a lot of corrosion (it was 16 years old). By doing the replacement myself I saved over $250. Seems to be a quality replacement, but time will tell.

### ⭐⭐⭐⭐ Replacement for Goodman Single Pole / 1 Pole 30 Amp Condenser Contactor B1360321
*by B***A on May 21, 2024*

Bought this Contactor to replace my old 20+ year old Contactor while servicing other A/C components. There was a tiny chip out of the housing where two sections meet that was probably done during assembly in the factory. No internals are left exposed, but just mentioning this as a side note. Tip: If you order this, I'd suggest only ordering it with other lightweight products, because Amazon will ship it in a bag if it's a small order and it could be damage by heavier items in the bag. I ordered my Contactor with a heavy 1" NPT Tap and Drill Bit set and the Contactor box was in rough shape with the side poked through. Amazon's carelessness, not the seller.

## Frequently Bought Together

- Replacement for Goodman Single Pole / 1 Pole 30 Amp Condenser Contactor B1360321 by Replacement for Goodman
- Genteq C3355R Capacitor Dual Run Round 35/5 UF MFD 370V VAC 97F9834 (Replace Old GE# Z97F9834) 35 and 5 MFD at 370V
- Goodman 1.5 - 3.5 Ton Condenser Fan Motor

---

## Why Shop on Desertcart?

- 🛒 **Trusted by 1.3+ Million Shoppers** — Serving international shoppers since 2016
- 🌍 **Shop Globally** — Access 737+ million products across 21 categories
- 💰 **No Hidden Fees** — All customs, duties, and taxes included in the price
- 🔄 **15-Day Free Returns** — Hassle-free returns (30 days for PRO members)
- 🔒 **Secure Payments** — Trusted payment options with buyer protection
- ⭐ **TrustPilot Rated 4.5/5** — Based on 8,000+ happy customer reviews

**Shop now:** [https://www.desertcart.ae/products/29218792-replacement-for-goodman-single-pole-1-pole-30-amp-condenser](https://www.desertcart.ae/products/29218792-replacement-for-goodman-single-pole-1-pole-30-amp-condenser)

---

*Product available on Desertcart United Arab Emirates*
*Store origin: AE*
*Last updated: 2026-04-23*